Sterilization Indicators

Changing appearances in color or pattern, the sterilization indicators visually show if cleaning conditions are passing or procedures have been completed. Eliminating any confusion or possibility instruments will not be sterile, indicators are used routinely in clinical and research environments where contamination elimination is crucial. With the temperature resistance required to endure the purification, the sterilization indicators are available in different forms such as tapes, ampoules, and sticks. Geobacillus stearothermophilus spores demonstrate a high resistance towards steam and vaporized hydrogen peroxide and are therefore used in BIs that monitor these sterilization processes.


SearchPresentationType-VERTICAL
 
 
 
SearchResultCount:"22"
Searching List View List View Easy View 
Sort by:
 
 
 
 

Product Image
Description:   Plain. Self-adhesive, nontoxic. Purple to green color change upon exposure to ethylene oxide. The exposure required for a color change is 600mg/L of ethylene oxide for a minimum of 30 minutes at 50-70% RH and 30[degree]C. Conform to AAMI ST60 and ISO 11140-1.
Catalog Number: 19872-028
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   Imprinted. Self-adhesive, nontoxic, chemical process indicator changes from yellow to blue and reveals imprint when exposed to 3 to 6mg/L vapor hydrogen peroxide in a complete STERRAD* 100 or 100 S Sterilization System cycle.
Catalog Number: 19872-068
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   For radiation sterilization. Bacillus pumilus spore population per strip: 1e6. Size: 6x30mm. 18-month shelf-life. Individually packaged in glassine envelopes. Instructions for use, certified population, D-value, Z-value, survival/kill data, and expiration date included.
Catalog Number: 19872-008
Supplier: NAMSA



Quantity:
 
 
 
   
Product Image
Description:   For steam sterilization. Biological indicator provides validation that bacterial spores have been completely destroyed. Provided in 10mL pharmaceutical vials. Population of 1e6 Geobacillus stearothermophilus spores per 0.1mL. Meets USP and ISO 11138-1 standards.
Catalog Number: 19872-024
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   For ethylene oxide or dry heat sterilization. Bacillus atrophaeus spore population per strip: 1e6. 2x10mm. 24-month shelf-life. Individually packed in glassine envelopes. With instructions, certified population, D-value, Z-value, survival/kill data, expiration date.
Catalog Number: 19872-014
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   Self Contained Biological Indicator (SCBI) for monitoring steam sterilization process efficacy. SCBI consists of inoculated disc, media ampoule which transitions color within 24 hours of exposure if cycle was not effective. 105 population level of G.sterothermophilus spores.
Catalog Number: 95029-702
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   Imprinted. Self-adhesive, nontoxic. Purple to green color change upon exposure to ethylene oxide reveals imprint. Color change requires exposure to 600mg/L of ethylene oxide for minimum of 30 minutes at 50-70% RH and 30[degree]C. Conform to AAMI ST60 and ISO 11140-1.
Catalog Number: 19872-032
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   For steam sterilization. Geobacillus stearothermophilus spore population per strip: 1e6. Size: 2x10mm. 18-month shelf-life. Individually packaged in glassine envelopes. WIth instructions, certified population, D-value, Z-value, survival/kill data, expiration date.
Catalog Number: 19872-016
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   Plain. Self-adhesive, nontoxic. Yellow to red color change upon exposure to gamma or electron beam radiation. Minimum 15kGy irradiation for sufficient endpoint color. Meet AAMI ST60 and ISO 11140-1, Section 6 for Class 1 Process Indicators.
Catalog Number: 19872-034
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Image Unavailable
Description:   Biological Indicator Disc, for Monitoring Hydrogen Peroxide/Plasma Processes, Geobacillus stearothermophilus Cell Line 7953, Diameter: 9 mm, 106 population level, ISO 11138-1 compliant, Individually Packaged in Tyvek* Pouches
Catalog Number: 75840-974
Supplier: NAMSA



Quantity:
 
 
 
   
Product Image
Description:   Self Contained Biological Indicator (SCBI) for monitoring EO sterilization process efficacy. SCBI consists of inoculated disc, media ampoule which transitions color within 48 hours of exposure if cycle was not effective. 106 population level of Bacillus atrophaeus spor
Catalog Number: 95029-700
Supplier: NAMSA



Quantity:
 
 
 
   
Product Image
Description:   For steam sterilization. Geobacillus stearothermophilus spore population per strip: 1e6. Size: 6x30mm. 18-month shelf-life. Individually packaged in glassine envelopes. With instructions, certified population, D-value, Z-value, survival/kill data, and expiration date.
Catalog Number: 19872-004
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   For ethylene oxide or dry heat sterilization. Biological indicator provides validation that bacterial spores have been completely destroyed. Provided in 10mL pharmaceutical vials. Population of 1e6 Bacillus atrophaeus spores per 0.1mL. Meets USP and ISO 11138-1 standards.
Catalog Number: 19872-022
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   For ethylene oxide or dry heat sterilization. Bacillus atrophaeus spore population per strip: 1e6. Size: 6x30mm. 18-month shelf-life. Individually packaged in glassine envelopes with instructions, certified population, D-value, Z-value, survival/kill data, expiration date.
Catalog Number: 19872-000
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   Imprinted. Self-adhesive, nontoxic. Yellow to red color change upon exposure to gamma or electron beam radiation reveals imprint. Minimum 15kGy irradiation for sufficient endpoint color. Meet AAMI ST60 and ISO 11140-1, Section 6 for Class 1 Process Indicators.
Catalog Number: 19872-038
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    
Product Image
Description:   For steam sterilization. Geobacillus stearothermophilus spore population per strip: 1e5. Size: 6x30mm. 18-month shelf-life. Individually packaged in glassine envelopes. With instructions, certified population, D-value, Z-value, survival/kill data, and expiration date.
Catalog Number: 19872-006
Supplier: NAMSA



Quantity:
 
 
 
Certificate Certificates    