Easy access to products and protocols for research use only in the identification of 2019-nCoV based on Centers for Disease Control and Prevention (CDC) recommendations
So much has changed during this unprecedented time, except your ability to count on Avantor. We continue to set science in motion to create a better world by providing you with the right solutions to keep moving forward.
Our solutions, developed with you as our focus, are crafted by our team and network of professionals with advanced degrees in science, quality control, engineering, manufacturing and industry experience.
Avantor supports end-to-end fluid management solutions – including peristaltic pumps and aseptic fluid transfer solutions – that are reliable and customer-centric, helping bioprocessing manufacturers meet their research and production goals.
A strong, vibrant research and development group is the lifeblood of all industries. VWR will support you from the latest life science products to the guaranteed purity of organic building blocks...
VWR is ready to support your production facility with reliable access to raw materials and essential supplies. We can also help you increase productivity...
VWR is proud of our years of experience providing choice and excellent service to the Industrial market from Food & Beverage, Petrochemical, Environmental Testing, Waste Water, Cosmetics, Consumer Goods, Agriculture and more...
VWR is your complete source for workplace supplies. Binders, calendars, pens, cleaning and sanitation supplies, and office equipment are just some of the essential products we offer...
New Avantor® J.T.Baker® premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust.
Avantor Services provides a wide range of specialized services and digital solutions to help you solve complex challenges.
We’ve built our reputation on consistent, comprehensive mastery of day-to-day operations, allowing lab, clinical, and production environments to focus their high-value resources on core scientific priorities.
As our customers’ needs have evolved, so have our capabilities. We have become experts in scientific operations, improving performance with sophisticated solutions and providing guidance on best practices.
You can select and customize services for peak efficiency, quality, and accelerated innovation.
Atomizers deliver a uniform spray mist of reagents onto thin layer chromatography plates whereas Nebulizers provide a fine mist for elemental analysis in spectrometric and spectroscopic applications . VWR offers wide range of atomizers, analytical nebulizers and supplies for atomic absorption. Many reagent atomizers have a screw-thread joint for connecting the sprayer head to the flask, and sprays can operate on very little air pressure, making them functional in a range of environmental conditions. Certain sprayers feature specially designed heads to eliminate the formation of droplets and spattering.
Description:
Capacity: 125mL; Joint Size: [ST] 24/40. For spraying chromagenic reagents when using thin layer or paper chromatography. Complete unit consists of spray head, flask and LG-1004-108 plastic clamp.
Description:
GemCone* high dissolved solids Nebulizer for samples up to 20%. Analyze samples with higher solids concentration, require an end cap for use with Ryton Scott Spray Chambers. High solids version.
Description:
Concentric Teflon* Nebulizer - PFA-ST. Ultra clean PFA Teflon nebulizer with exchangeable capillaries to provide flow rates from 100-400 uL/min. For use with autosamplers
Description:
Nebulizer, High Sensitivity with Pt/lr Capillary Assembly, Inert plastic body with red adjusting ring, for PerkinElmer Analyst 100/300/700/800, 5100 PC, 5000, 3300, 3110, 3100, and Atomic absorption spectroscopy
Description:
GemTip* Crossflow Nebulizer, Contains a PPS (carbon-filled polyphenyl sulfide) end cap with a GemTip* clear sapphire sample tip and red ruby argon tip
Description:
For use with the Optima 8x00 ICP-OES. It is an excellent general purpose nebulizer for the analysis of strong mineral acids (including HF) and samples with less than 5% dissolved solids.
Description:
SeaSpray Nebulizer 0.4mL/min for ELAN/NexION, High physical reproducibility 1%, TDS tolerance, Typically up to 20%, High tolerance to particulates, Typically up to 75um, Low RSD's due to highly accurate construction
Description:
Twister Cyclonic Spray Chamber with Helix for Optima 2000/4000/5000DV. The Baffled Cyclonic Spray Chamber features a central transfer tube which acts as a secondary particle separator, Helping to separate larger aerosol particles from the sample.
Description:
Quartz SeaSpray Concentric Nebulizer-FH uptake=1ml/min for samples with high dissolved solids and offers outstanding nebulization efficiency for trace level analysis
Description:
Nebulizer Concentric Glass, MEINHARD* Type C, include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control, Close fabrication control, For use with high dissolved solids solution
Description:
Nebulizer Assembly for High Sensitivity with Tantalum Capillary. High Sensitivity Provide maximum sensitivity, Precision, And freedom from analytical interferences. Available with durable platinum alloy capillary
Description:
GemTip Replacement, Cross-Flow II Nebulizer for ICP-MS, Includes a color coded set of ruby and sapphire GemTips optimized, Orifice size: argon, (0.23mm, 0.009in) ruby red; sample, (0.34mm, 0.013in) clear
Description:
Designed to efficiently deliver a cleanser through the nebulizer capillary to dislodge particle build-up and thoroughly clean it. This is effective for OpalMist, PolyCon and DuraMist nebulizers.
Description:
The cyclonic spray chamber is an integral part of the sample introduction system responsible for filtering the sample mist to permit the appropriate droplet size distribution to reach the plasma. The cyclonic spray chamber relies on momentum to efficient.
Description:
Quartz Cyclonic Spray Chamber for Optima 5300DV - 7mm baffle, Drain line included (no aux. Gas port) (connects directly to ESI injectors, An adapter is needed to connect to other injectors)
Description:
MEINHARD Type K Concentric Glass Nebulizer. The MEINHARD* concentric glass nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, Reproducible and self-aligning aerosol, And close fabrication control.
Description:
Twister Cyclonic Spray Chamber with Helix for Optima 4300V, 5300V. The Baffled Cyclonic Spray Chamber features a central transfer tube which acts as a secondary particle separator, Helping to separate larger aerosol particles from the sample.
Description:
Tracey Cyclonic Spray Chamber with Helix for Optima 2000/4000/5000DV. Standard and O-Ring Free Glass Cyclonic Spray Chambers can be used with either GemCone or Concentric Glass Nebulizers.
Description:
GemCone High Dissolved Solids Nebulizer Kit. Includes GemCone High Dissolved Solids Nebulizer and Quick Disconnect Tubing for Optima 2X00/4X00/5X00/7X00.
Description:
Twister Cyclonic Spray Chamber with Helix for Organics (4mm baffle) for Optima 2000/4000/5000DV. The Baffled Cyclonic Spray Chamber features a central transfer tube which acts as a secondary particle separator, Helping to separate larger aerosol particles from the sample.
Description:
MicroMist Nebulizer, 0.2mL/min uptake for Elan, Optima 3000RL, Plasma Series. The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 - 0.6 mL/min.EzyFit connector with 1.3 mm o.d. X 0.50 mm i.d
Description:
Baffled Cyclonic Spray Chamber Kit. The cyclonic spray chamber is an integral part of the sample introduction system responsible for filtering the sample mist to permit the appropriate droplet size distribution to reach the plasma.
Description:
Atomizer. 125 mL. 188 mm. For use in spraying reagents in thin layer chromotography. With full length [standard taper] 24/40 joint between reservoir and spraying device.
Description:
Atomizer. 250 mL. 208 mm. For use in spraying reagents in thin layer chromotography. With full length [standard taper] 24/40 joint between reservoir and spraying device.
Description:
With Aux Port & Helix, 50 mL cyclonic, Borosilicate glass, It features a central transfer tube which acts as a secondary particle separator, Helping separate larger aerosol particles from the sample. The position of the baffle ensure smooth draining and improved precision
Description:
Baffled Cyclonic Spray Chamber 4mm id. The internal baffle design has two important characteristics: The distance between the bottom of the baffle and the chamber wall is carefully controlled so that droplets cannot form on the bottom of the baffle.
Description:
Scott spray chamber and crossflow nebulizer. Complete Torch and Sample Introduction Module including complete ICP torch, Mounting block, 2 mm alumina injector, Scott spray chamber, And Crossflow Nebulizer.
Description:
PC3-LT DV-with PFA-ST Nebulizer. +2DegC for aqueous / -20DegC for organic solvents, Improved stability, Improved rinse out cycle times Reduces oxides and polyatomic interferences, Reduced sample and skimmer cone cleaning, No separate chiller required, No antifreeze
Description:
Low-flow GemCones permit lower nebulizer gas flow rates, Useful for spectral lines with high excitation energies and for providing a more robust plasma. GemCone Nebulizers require an end cap for use with Ryton Scott Spray Chamber
Description:
SeaSpray Nebulizer, 2mL/min uptake for Elan, Optima 3000RL, Plasma Series. The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization efficiency for trace level analyses.