Easy access to products and protocols for research use only in the identification of 2019-nCoV based on Centers for Disease Control and Prevention (CDC) recommendations
So much has changed during this unprecedented time, except your ability to count on Avantor. We continue to set science in motion to create a better world by providing you with the right solutions to keep moving forward.
Our solutions, developed with you as our focus, are crafted by our team and network of professionals with advanced degrees in science, quality control, engineering, manufacturing and industry experience.
Avantor supports end-to-end fluid management solutions – including peristaltic pumps and aseptic fluid transfer solutions – that are reliable and customer-centric, helping bioprocessing manufacturers meet their research and production goals.
A strong, vibrant research and development group is the lifeblood of all industries. VWR will support you from the latest life science products to the guaranteed purity of organic building blocks...
VWR is ready to support your production facility with reliable access to raw materials and essential supplies. We can also help you increase productivity...
VWR is proud of our years of experience providing choice and excellent service to the Industrial market from Food & Beverage, Petrochemical, Environmental Testing, Waste Water, Cosmetics, Consumer Goods, Agriculture and more...
VWR is your complete source for workplace supplies. Binders, calendars, pens, cleaning and sanitation supplies, and office equipment are just some of the essential products we offer...
New Avantor® J.T.Baker® premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust.
Avantor Services provides a wide range of specialized services and digital solutions to help you solve complex challenges.
We’ve built our reputation on consistent, comprehensive mastery of day-to-day operations, allowing lab, clinical, and production environments to focus their high-value resources on core scientific priorities.
As our customers’ needs have evolved, so have our capabilities. We have become experts in scientific operations, improving performance with sophisticated solutions and providing guidance on best practices.
You can select and customize services for peak efficiency, quality, and accelerated innovation.
The Equipment & Instrument Service Team’s focus is to provide comprehensive service solutions for our customers. We provide validation, calibration, preventative maintenance, and extended warranties on all equipment & instruments in and around the laboratory.
Description:
White Plain Circles, Polypropylene Backed. These filters have been developed for applications involving aggressive organic solvents, strong acids and alkalis. The filters are backed with a polypropylene support web to facilitate handling.
Description:
7cm diameter. For collecting solids in water, monitoring pollutants, filtering particulate components in sea water, and for harvesting lymphocytes in incorporation trials. Used in RIA procedures. Binder free. Fine porosity. Fast flow. 1.2um particle retention.
Description:
The fastest ashless filter paper, recommended for analytical procedures involving coarse particles or gelatinous precipitates (e.g., iron or aluminum hydroxides).
Description:
Nuclepore Hydrophilic Polycarbonate Membrane, Pore Size: 0.2 um, 47 mm circle (100 pcs), Track-etched for highly defined pore size and high pore density, Treated with polyvinylpyrrolidone (PVP) to render it hydrophilic, Low, consistent ash and low tare weights
Description:
Nuclepore Hydrophilic Polycarbonate Membrane, Pore Size: 0.2 um, 90 mm circle (25 pcs), Track-etched for highly defined pore size and high pore density, Treated with polyvinylpyrrolidone (PVP) to render it hydrophilic, Low, consistent ash and low tare weights
Description:
7.0cm diameter. For a wide range of laboratory applications, liquid clarification, gas filtration, air pollution analysis, and soil analysis. Medium porosity. Medium flow rate. 11um particle retention.
Description:
Slit septa for high throughput automation. Septa made of PTFE membrane and silicone rubber. With PES membrane for biological samples requiring low protein binding media. Pore size: 0.2um. Filtering capacity: 0.5mL. Maximum operating temperature: 50[degree]C.
Description:
0.8um Metricel black polyethersulfone (PES) gridded filters. 0.8um black membrane is often used in the beverage industry for better throughput. 200 pieces per box, 5 boxes per pack (1000 membranes per pack)
Description:
4.7cm diameter. For coarse particles or gelatinous precipitates. For iron or aluminum hydroxides. For air pollution analysis as a paper tape for impregnation when determining gaseous compounds. Coarse porosity. Fast flow rate. 20-25um particle retention.
Description:
With 30-40um PP/PE (polypropylene/polyethylene) non-woven media provide fast and efficient removal of particulates in aqueous samples. Typical applications include: multiplexing, general sample prep, gross fractionation, cell harvesting, etc. 5 per pack
Description:
Reduce filtration time; optimised for biological, pharmaceutical, and sterilizing filtration requirements. Fast filtration with superior flow rates and high throughputs. Low protein binding and extensive drug compatibility for critical applications.
Description:
0.1um pore size. 90mm diameter. Plain. Nonsterile. Supor hydrophilic polyethersulfone membrane for high flow rate, low protein binding, low extractables. Stronger than acetate and nitrate membranes. Very high water flow, fluid filtration capacity. Autoclavable. 100/pk.
Description:
Benchkote sheet, will protect the top buffer trays from buffer spillages and salt deposits, Smooth, absorbent Whatman paper absorbs spills, Laminated polyethylene layer prevents flow-through to the working surface, for ÄKTA system, Convenient and easy to use
Description:
Pad. 50 sheets. 45.7Wx55.9Lcm. Polyethylene coating prevents liquids from penetrating through the paper. Keeps surfaces free from stains, corrosion or bacterial contamination. Use to localize and hold reagent spillage. Tear resistant.
Description:
An anodized aluminum manifold. Designed and optimized for the vacuum filtration of the AcroPrep and AcroWell lines. Includes O-ring and gasket.
Description:
Filter Paper, Grade: 934 Ah For Volatile, pre-washed, dried, cooled, and weighed filters with certified mass loss between washing and drying steps of the lesser of less than 0.5 mg or 4% in accordance US EPA Lab Method 2540 parts C and D, testing filters available, Size: 42.5 mm
Description:
For the preparation of hard-to-filter samples. Pigment-free polypropylene housing. Process three to seven times more sample compared to an unprotected membrane. 13 mm and 25 mm diameter syringe filters.
Description:
0.2um pore size. 25mm diameter. Non-sterile. Anopore* aluminum oxide membrane with honeycomb pore structure. Compatible with most solvents and aqueous materials. Molded polypropylene housing. Luer lock fittings. For samples up to 100mL. <150uL hold up volume.
Description:
Clear polystyrene plates with Whatman GF/C glass fiber filter media. Long drip directors eliminate well-to-well contamination during the filtration process. Use for DNA template cleanup, cell capture, and for removal of unwanted debris.
Description:
Clear polystyrene plates with 0.45um hydrophilic PVDF membrane filter media. Long drip directors eliminate well-to-well contamination during filtration process. Use for DNA template cleanup, cell capture, and for removal of unwanted debris.
Description:
22 x 60 mm - thickness 2.0 mm Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder.
Description:
Multi-Barrier Pouch, For EasiCollect+ Card, For transporting or storing FTA Gene Cards, Mini Cards or Micro Cards, Laminated layers that protect the card from exposure to gas of liquid contamination, tamper-evident seal maintains security, Dimension: 4x4.5in
Description:
11.0cm diameter. Ashless paper for gravimetric analysis with very fine particle retention. Thinner than Grade 42 with lower ash weight per sample and almost twice the flow rate. Fine porosity. Slow flow rate. 3um particle retention.
Description:
0.2um pore size. 10mm diameter. Non-sterile. Anopore* aluminum oxide membrane with honeycomb pore structure. Compatible with most solvents and aqueous materials. Molded polypropylene housing. Luer lock fittings. For samples up to 10mL. <20uL hold up volume.
Description:
0.45um pore size. 13mm diameter. Hydrophobic PTFE for organic-based samples. Units contain two prefilters [graded density Multigrade GMF 150 (10:1um) and Grade GF/F (0.7um)] that allow filtration of hard-to-filter samples with minimal hand force. For samples up to 10ml.
Description:
Syringe Filter, GD/X 13, nonsterile, polyethersulfone, 1.00 um, 13 mm PES filtration medium, Filters greatly reduce the need to carry out separate prefiltration step with difficult-to-filter samples, Requires less hand pressure, even with the most difficult samples, pack150
Description:
7cm filter diameter. 115ml volume. Designed for use with Whatman glass microfiber filters. Reservoir, base and stem are borosilicate glass with ground contact flanges. With three leakproof, plastic-coated clamps and transparent acrylic support plate. 15.9cm high.
Description:
15.0cm diameter. Ashless paper for gravimetric analysis with very fine particle retention. Thinner than Grade 42 with lower ash weight per sample and almost twice the flow rate. Fine porosity. Slow flow rate. 3um particle retention.
Description:
0.45um pore size. 25mm diameter. High-loading capacity for aqueous and organic-based samples. Graded density Multigrade GMF 150 (10:1um) prefilter with a selection of glass microfiber filters for difficult to filter samples. For samples>10ml.
Description:
3.7cm diameter. For suspended solids in water analysis. Used for harvesting lymphocytes in incorporation trials, mixed lymphocyte culture tests, scintillation counting techniques, air monitoring. Binder free. Fine porosity. Fast flow. 1.5um particle retention.
Description:
0.45um pore size. 13mm diameter. For aqueous and organic-based samples. Low protein binding polyvinylidene fluoride membrane. Two prefilters [graded density Multigrade GMF 150 (10:1um) and Grade GF/F (0.7um)] allow filtration of hard-to-filter samples. For up to 10ml.
Description:
28 x 60 mm - thickness 2.0 mm Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder.
Description:
11.0cm diameter. For critical gravimetric analysis. Widely used for precipitates with tendencies toward colloidal dispersion. Suitable for gravity or low suction filtration. Fine porosity. Slow flow rate. 2.5um particle retention.
Description:
9.0cm diameter. For critical gravimetric analysis. Widely used for precipitates with tendencies toward colloidal dispersion. Suitable for gravity or low suction filtration. Fine porosity. Slow flow rate. 2.5um particle retention.