Easy access to products and protocols for research use only in the identification of 2019-nCoV based on Centers for Disease Control and Prevention (CDC) recommendations
So much has changed during this unprecedented time, except your ability to count on Avantor. We continue to set science in motion to create a better world by providing you with the right solutions to keep moving forward.
Our solutions, developed with you as our focus, are crafted by our team and network of professionals with advanced degrees in science, quality control, engineering, manufacturing and industry experience.
Avantor supports end-to-end fluid management solutions – including peristaltic pumps and aseptic fluid transfer solutions – that are reliable and customer-centric, helping bioprocessing manufacturers meet their research and production goals.
A strong, vibrant research and development group is the lifeblood of all industries. VWR will support you from the latest life science products to the guaranteed purity of organic building blocks...
VWR is ready to support your production facility with reliable access to raw materials and essential supplies. We can also help you increase productivity...
VWR is proud of our years of experience providing choice and excellent service to the Industrial market from Food & Beverage, Petrochemical, Environmental Testing, Waste Water, Cosmetics, Consumer Goods, Agriculture and more...
VWR is your complete source for workplace supplies. Binders, calendars, pens, cleaning and sanitation supplies, and office equipment are just some of the essential products we offer...
New Avantor® J.T.Baker® premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust.
Avantor Services provides a wide range of specialized services and digital solutions to help you solve complex challenges.
We’ve built our reputation on consistent, comprehensive mastery of day-to-day operations, allowing lab, clinical, and production environments to focus their high-value resources on core scientific priorities.
As our customers’ needs have evolved, so have our capabilities. We have become experts in scientific operations, improving performance with sophisticated solutions and providing guidance on best practices.
You can select and customize services for peak efficiency, quality, and accelerated innovation.
The Equipment & Instrument Service Team’s focus is to provide comprehensive service solutions for our customers. We provide validation, calibration, preventative maintenance, and extended warranties on all equipment & instruments in and around the laboratory.
Description:
0.45um GN-6 membrane. White, gridded. 300mL capacity. Individually bagged and overpack-bagged for more efficient transport and sterilization within an isolator. Simple squeeze separation design for easy membrane retrieval. 20/pk.
Description:
Acid-washed paper with ash content of approximately 0.01%, low magnesium, for the determination of trace elements (Mg, Mn, Co, Cu, Mo, B).
Description:
Supracap* 100 Filter Capsule, with Media grade PDP8, 13mm hose barb fitting, pore size rating of 6-30 um, Designed to capture whole or crushed cells, general cell removal from culture media of bacteria, yeast or mammalian, Single Use, Size: 10in Depth
Description:
27.0cm diameter. For coarse particles and gelatinous precipitates. Thick and strong. High loading capacity. High wet strength. Creped surface. Not for nitrogen determinations. Coarse porosity. Faster flow rate than other qualitative grades. 30um particle retention.
Description:
With 0.45um hydrophobic PTFE membrane. Made of chemically-resistant, biologically-inert polypropylene. Feature extended flow directors to eliminate splattering and crosstalk of filtrate. Serialized bar code label. Robotics-friendly design.
Description:
The Paper are made from pure cellulose without any additives and do not contain any substances which could influence the growth of the seeds.
Description:
0.02um pore size. 10mm diameter. Sterile. Anopore* aluminum oxide membrane with honeycomb pore structure. Compatible with most solvents and aqueous materials. Molded polypropylene housing. Luer lock fittings. For samples up to 10mL. <20uL hold up volume.
Description:
Nylon hydrophilic membrane has excellent compatibility with esters, bases, and alcohols, and requires no prewetting. Polypropylene housing. AutoPack* tube format for workstations. Pore size: 0.45um. Filtration area: 3.9cm2. Hold-up volume: <125uL.
Description:
Slit septa for high throughput automation. Septa made of PTFE membrane and silicone rubber. With PTFE membrane for chemically agressive samples. Pore size: 0.45um. Filtering capacity: 0.5mL. Maximum operating temperature: 50[degree]C.
Description:
Designed for high particulate loaded samples. Eliminate sample contamination and allow you to filter even the most difficult samples with less hand pressure. Samples up over 10ml.
Description:
12.5cm diameter. For a wide range of laboratory applications, liquid clarification, gas filtration, air pollution analysis, and soil analysis. Medium porosity. Medium flow rate. 11um particle retention.
Description:
TF Disposable Filter Capsule, Polycap*, For research use only, Hydrophobic Polytetrafluoroethylene membrane, Autoclavable, Not recommended or intended for diagnosis of disease in humans or animals, pack1
Description:
Slit septa for high throughput automation. Septa made of PTFE membrane and silicone rubber. Nylon membrane filters samples containing aqueous or organic solvents with 3-10 pH. Pore size: 0.2um. Filtering capacity: 0.5mL. Maximum operating temperature: 50[degree]C.
Description:
0.8um pore size. 293mm diameter. Plain, nonsterile. Supor hydrophilic polyethersulfone membrane for high flow rate, low protein binding, low extractables. Stronger than acetate and nitrate membranes. Very high water flow, fluid filtration capacity. Autoclavable. 25/pk.
Description:
25.7cm diameter. For collecting fine precipitated proteins. Specified for TCLP analysis. Use with GF/D for effective clarification of biochemical/biological and other difficult to clarify fluids. Binder free. Fine porosity. Medium flow. 0.7um particle retention.
Description:
Pore Size Rating Of 0.5-15 Um. Designed To Provide Maximum Throughput For Biological, Bioprocess And Pharmaceutical Filtration. This Media Configuration Provides High Dirt Holding Capacity And Good Membrane Protection.
Description:
2.4cm diameter. For suspended solids in water analysis. Used for harvesting lymphocytes in incorporation trials, mixed lymphocyte culture tests, scintillation counting techniques, air monitoring. Binder free. Fine porosity. Fast flow. 1.5um particle retention.
Description:
Polycarbonate Membrane Hydrophilic. These membranes are available in pore sizes ranging from 0.1 um to 12 um. Hydrophilic as standard, Cyclopore Polycarbonate Membranes can also be made hydrophobic upon request.
Description:
Sanitary Flange Inlet/Out And Pore Size Rating Of 0.5-15Um. Applications Include Biological, Bioprocess And Pharmaceutical Filtration. This Media Configuration Provides High Dirt Holding Capacity And Good Membrane Protection.
Description:
Folded Prepleated Grade 595 1/2 folded filters, 70 mm, 100/pk. Thin filter paper, medium-fast with medium to fine particle retention. Used for many routine analytical applications in different industries
Description:
0.2um pore size. 25mm diameter. Two prefilters [gradient density Multigrade GMF 150 (10:1um) and Grade GF/F (0.7um)] allow filtration of even the most difficult samples with minimal hand force. For samples>10mL. For aqueous and some organic-based samples.
Description:
Is a well-engineered product that offers high filtration efficiency and excellent filtrate purity due to its materials and methods of manufacture.
Description:
VWR* Whatman Grade GF 10 Glass Microfiber Filters with Binder, Filtration Speed: Medium, Air Flow Rate: 12 s/100 ml/1.56 cm raised to 2, Material: Borosilicate glass, weighing aid for infrared weighing and as a roll filter. Dimensions: 90 mm
Description:
Sanitary Flange Inlet/Outlet And Pore Size Rating Of 8û20Um. Applications Include Coarse Filtration In Biotechnology, Including Filtration Of Fermentor Broth, Cell Culture, Therapeutical Proteins, Vaccines, Diagnostics And Blood Products.
Description:
0.2um pore. 1000cm2 filtration area. 9.5-12.7mm stepped barb connection. PTFE membrane in a polypropylene housing. No glue, adhesives, metal, epoxy, or other extraneous materials are used in construction. Broad chemical resistance. Fused seals. Autoclavable.
Description:
Variety of pore sizes and membrane types for prefiltration and clarification. Meets virtually all aqueous sample filtration needs. Protect columns and instrumentation against particulate build-up.
Description:
47mm diameter. For use in US EPA Method 1311 Toxicity Characteristics Leaching Procedure and in Zero Headspace Extractors for volatile analysis and more. Binder-free borosilicate glass. No added extractables. Fine porosity. Medium flow rate. 0.7um particle retention. 50/pk.
Description:
Use with the Pall Life Sciences Ultrasette Lab Tangential Flow Device. Includes one 3.2mm NPT 0–60 psig pressure gauge, one polypropylene tee, 2 barb to NPT connectors, 2 stainless steel tubing clamps, 1 screw clamp.
Description:
A universal solution for numerous filtration applications. Can be used with most organic solvents and aqueous materials, and they are suitable for sample volumes up to 100 ml.
Description:
Supracap* 50 Filter Capsule, with Media grade PDP8, luer fitting, pore size rating of 6-30 um, Designed to capture whole or crushed cells, general cell removal from culture media of bacteria, yeast or mammalian, Single-use, robust, Surface area: 22 cm2
Description:
0.2um pore size. 25mm diameter. Hydrophilic nylon filter for aqueous and organic-based samples. Two prefilters [graded density Multigrade GMF 150 (10:1um) and Grade GF/F (0.7um)] allow filtration of hard-to-filter samples with minimal hand force. For samples >10ml.
Description:
GD/X 13 Syringe Filter, nonsterile, 2.7 um, 13 mm glass microfiber filtration medium, for filtration of high particulate loaded samples, Filters greatly reduce the need to carry out separate prefiltration step with difficult-to-filter samples, pack150
Description:
Filter Paper, Grade: 934 Ah For Volatile, pre-washed, dried, cooled, and weighed filters with certified mass loss between washing and drying steps of the lesser of less than 0.5 mg or 4% in accordance US EPA Lab Method 2540 parts C and D, testing filters available, Size: 90 Mm.
Description:
AcroPrep Advance filter plates. 96-well, 1 mL with 0.45um Supor (polyethersulfone) membrane. Filter plates are constructed of polypropylene and designed for use in a variety of applications.
Description:
Variety of pore sizes and membrane types for prefiltration and clarification. Meets virtually all aqueous sample filtration needs. Protect columns and instrumentation against particulate build-up.