Easy access to products and protocols for research use only in the identification of 2019-nCoV based on Centers for Disease Control and Prevention (CDC) recommendations
So much has changed during this unprecedented time, except your ability to count on Avantor. We continue to set science in motion to create a better world by providing you with the right solutions to keep moving forward.
Our solutions, developed with you as our focus, are crafted by our team and network of professionals with advanced degrees in science, quality control, engineering, manufacturing and industry experience.
Avantor supports end-to-end fluid management solutions – including peristaltic pumps and aseptic fluid transfer solutions – that are reliable and customer-centric, helping bioprocessing manufacturers meet their research and production goals.
A strong, vibrant research and development group is the lifeblood of all industries. VWR will support you from the latest life science products to the guaranteed purity of organic building blocks...
VWR is ready to support your production facility with reliable access to raw materials and essential supplies. We can also help you increase productivity...
VWR is proud of our years of experience providing choice and excellent service to the Industrial market from Food & Beverage, Petrochemical, Environmental Testing, Waste Water, Cosmetics, Consumer Goods, Agriculture and more...
VWR is your complete source for workplace supplies. Binders, calendars, pens, cleaning and sanitation supplies, and office equipment are just some of the essential products we offer...
New Avantor® J.T.Baker® premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust.
Avantor Services provides a wide range of specialized services and digital solutions to help you solve complex challenges.
We’ve built our reputation on consistent, comprehensive mastery of day-to-day operations, allowing lab, clinical, and production environments to focus their high-value resources on core scientific priorities.
As our customers’ needs have evolved, so have our capabilities. We have become experts in scientific operations, improving performance with sophisticated solutions and providing guidance on best practices.
You can select and customize services for peak efficiency, quality, and accelerated innovation.
The Equipment & Instrument Service Team’s focus is to provide comprehensive service solutions for our customers. We provide validation, calibration, preventative maintenance, and extended warranties on all equipment & instruments in and around the laboratory.
Description:
For use with 0.64cm (1/4”) thermocouples. Has an outer Viton* o-ring to form a grease-free, airtight seal between adapter and listed size of outer joint.
Description:
Adapter has an outer luer joint that provides a convenient way to connect solid phase extraction (SPE) catriges, tubes or syringes to a standard taper inner joint. 24/40 Inner, with the addition of a 2mm PTFE stopcock.
Description:
Adapter used for reduced pressure filtration with plain stem buchner funels. Top has a Heavy Duty tooled flare to accept the listed pluro stopper. 14/20.
Description:
Adapter, 0-12mm Valve. Similar to the AF-0072 adapter, but with the Chem-Cap valve at a 90[degree] angle to two #15 o-ring joints. Available in 0-4mm, 0-8mm or 0-12mm valve sizes. Each adapter is supplied complete with two #116 Viton o-rings.
Description:
Overall Height: 110mm. Joint size: 14/20. Flange I.D; 23mm; Pluro Stopper: #2. Adapter used for reduced pressure filtration with plain stem buchner funnels. Top is flared to accept the listed size pluro stopper. The hose connection has an O.D.
Description:
Tubing O.D.xI.D; 7.0x4.0mm. Inner joint manufactured to the same specifications found on medical and research syringes. Complies with Federal Specification CG-S-921b and USAST Standard Z70.1.
Description:
Adapter, 0-8mm Valve. Adapter has two #15 o-ring joints connected in-line via a Chem-Cap valve. Available with either 0-4mm or 0-8mm valve sizes. Each adapter is supplied complete with two #116 Viton o-rings.
Description:
HxW: 100x60mm. Joint size: 19/22. Used to regulate the flow of gases or liquids into reaction systems. Stopcock has a bore of 2mm and is supplied complete with a CG-423 retaining clip. Hose connection has an O.D. of 8mm at the middle serration.
Description:
Adapter, 0-8mm Valve. Similar to the AF-0072 adapter, but with the Chem-Cap valve at a 90[degree] angle to two #15 o-ring joints. Available in 0-4mm, 0-8mm or 0-12mm valve sizes. Each adapter is supplied complete with two #116 Viton o-rings.
Description:
Joint size: 14/20 Inner. Gas inlet adapter with a 2mm glass stopcock having a constant pressure retention device. Available with a choice of inner or outer standard taper joint. Top arm is 9mm O.D. medium wall tubing for with CG-3022 septum.
Description:
Used to regulate the flow of gases or liquids into reaction systems. Stopcock has a bore of 2mm and is supplied complete with a CG-423 retaining clip. Hose connection has an O.D. of 8mm at the middle serration. 14/20 Inner Joint
Description:
HxW: 105x50mm. Joint size: 14/20. With standard taper top outer and lower inner joints with sealed in drip tip. Serrated hose connection has an O.D. of 10mm at the largest serration for connection to vacuum source.
Description:
HxW: 130x30mm. Joint size: 29/42. Used to regulate the flow of gases or liquids into reaction systems. fluoropolymer resin stopcock has a bore of 2mm. Hose connection has an O.D. of 8mm at the middle serration.
Description:
Style 'A'. From #15 O-ring Joint to: 1/4in. straight glass tubing. Adapters for use with AF-0060 and AF-0061 manifolds that permit the manifold to be utilized with a multitude of standard glassware or tubing products.
Description:
2000ml. Joint size: Lower Inner: 45/50. Reservoir for use with CG-1192 and CG-1193 columns. Reservoir has a top 24/40 standard taper outer joint for use with CG-1195 flow controller, and the listed size lower inner joint.
Description:
HxW: 130x30mm. Joint size: 29/26. Used to regulate the flow of gases or liquids into reaction systems. fluoropolymer resin stopcock has a bore of 2mm. Hose connection has an O.D. of 8mm at the middle serration.
Description:
Style 'A'. From #15 O-ring Joint to: 1in. straight glass tubing. Adapters for use with AF-0060 and AF-0061 manifolds that permit the manifold to be utilized with a multitude of standard glassware or tubing products.
Description:
HxW: 130x50mm. Joint size: 29/42. Used to regulate the flow of gases or liquids into reaction systems. Stopcock has a bore of 2mm and is supplied complete with a CG-423 retaining clip. Hose connection has an O.D. of 8mm at the middle serration.
Description:
Overall Height: 230mm. Joint size: 29/42. Flange I.D; 38mm; Pluro Stopper: #4. Adapter used for reduced pressure filtration with plain stem buchner funnels. Top is flared to accept the listed size pluro stopper. The hose connection has an O.D.
Description:
H: 65mm. Joint size: 19/22. Adapter has an extra coarse disc between the serrated hose connection and the inner joint. Fritted disc prevents solids from being introduced into the system. Hose connection has a O.D. of 10mm at the largest serration.
Description:
Connection Adapter. Used to connect the AF-0300-13 manifold to the AF-0300-04 trap assembly. Adapter has a 0-20mm valve with two #20 o-ring joints at a 90[degree] angle. Supplied complete with two #214 Viton o-rings.
Description:
EVAPORATOR BUMP TRAPS. 24/40 Glass Adapter Only. Adapter which permits the connection of standard laboratory dram vials directly to the vapor tube or a bump trap of a rotary evaportor. Adapter has a top outer joint of the listed size and a 20-400 G.P.I.
Description:
HxW: 130x50mm. Joint size: 24/40. Used to regulate the flow of gases or liquids into reaction systems. Stopcock has a bore of 2mm and is supplied complete with a CG-423 retaining clip. Hose connection has an O.D. of 8mm at the middle serration.
Description:
H: 80mm. Joint size: 24/40. Adapter has a #7 Chem-Thread at the top for vacuum tight seal of plain stem thermometers or any other tube having an O.D. between 4 and 7mm. Supplied complete with a Celcon compression cap and Viton o-ring.
Description:
HxW: 185x30mm. Joint size: 24/40. Adapter has a 2mm fluoropolymer resin metering stopcock between a top outer and lower inner standard taper joints to permit flow control of fluids between apparatus.
Description:
Style 'A'. From #15 O-ring Joint to: 3/4in. straight glass tubing. Adapters for use with AF-0060 and AF-0061 manifolds that permit the manifold to be utilized with a multitude of standard glassware or tubing products.
Description:
Used to regulate the flow of gases or liquids into reaction systems. PTFE stopcock has a bore of 2mm. Hose connection has an O.D. of 8mm at the middle serration. 14/20 Inner Joint.
Description:
2000ml. Joint size: Lower Inner: 24/40. Reservoir for use with CG-1192 and CG-1193 columns. Reservoir has a top 24/40 standard taper outer joint for use with CG-1195 flow controller, and the listed size lower inner joint.
Description:
HxW: 65x60mm. Joint size: 24/40. Gas inlet adapter with a tube extending 200mm below the inner joint. Permits gas to be introduced at the bottom of larger reaction vessels or flasks. With serrated hose connection having an O.D. of 10mm at the largest serration.
Description:
Style 'D'. From #15 O-ring Joint to: 14/20 Outer Joint. Adapters for use with AF-0060 and AF-0061 manifolds that permit the manifold to be utilized with a multitude of standard glassware or tubing products.
Description:
Adapter, 0-4mm Valve. Similar to the AF-0072 adapter, but with the Chem-Cap valve at a 90[degree] angle to two #15 o-ring joints. Available in 0-4mm, 0-8mm or 0-12mm valve sizes. Each adapter is supplied complete with two #116 Viton o-rings.
Description:
5000ml. Joint size: Lower Inner: 45/50. Reservoir for use with CG-1192 and CG-1193 columns. Reservoir has a top 24/40 standard taper outer joint for use with CG-1195 flow controller, and the listed size lower inner joint.
Description:
For use with either 0.32cm (1/8”) thermocouples. Has an outer Viton* o-ring to form a grease-free, airtight seal between adapter and listed size of outer joint.
Description:
1000ml. Joint size: Lower Inner: 45/50. Reservoir for use with CG-1192 and CG-1193 columns. Reservoir has a top 24/40 standard taper outer joint for use with CG-1195 flow controller, and the listed size lower inner joint.
Description:
Tubing O.D.xI.D; 8.0x5.0mm. Outer joint manufactured to the same specifications found on medical and research syringes. Complies with Federal Specification CG-S-921b and USAST Standard Z70.1. Available tooled on three tubing sizes.
Description:
[standard taper] Joint; 14/10. Accommodation Range (mm); 2-5. Nominal Size (in.); 1/8. O-Ring Size; 105. Mod. GPI Thread; 13-425 For use with plain thermometers, pipets, syringes or other small items with an O.D.