Easy access to products and protocols for research use only in the identification of 2019-nCoV based on Centers for Disease Control and Prevention (CDC) recommendations
So much has changed during this unprecedented time, except your ability to count on Avantor. We continue to set science in motion to create a better world by providing you with the right solutions to keep moving forward.
Our solutions, developed with you as our focus, are crafted by our team and network of professionals with advanced degrees in science, quality control, engineering, manufacturing and industry experience.
Avantor supports end-to-end fluid management solutions – including peristaltic pumps and aseptic fluid transfer solutions – that are reliable and customer-centric, helping bioprocessing manufacturers meet their research and production goals.
A strong, vibrant research and development group is the lifeblood of all industries. VWR will support you from the latest life science products to the guaranteed purity of organic building blocks...
VWR is ready to support your production facility with reliable access to raw materials and essential supplies. We can also help you increase productivity...
VWR is proud of our years of experience providing choice and excellent service to the Industrial market from Food & Beverage, Petrochemical, Environmental Testing, Waste Water, Cosmetics, Consumer Goods, Agriculture and more...
VWR is your complete source for workplace supplies. Binders, calendars, pens, cleaning and sanitation supplies, and office equipment are just some of the essential products we offer...
New Avantor® J.T.Baker® premium conductive and non-conductive robotic tips deliver superior quality and reliable performance for results you can trust.
Avantor Services provides a wide range of specialized services and digital solutions to help you solve complex challenges.
We’ve built our reputation on consistent, comprehensive mastery of day-to-day operations, allowing lab, clinical, and production environments to focus their high-value resources on core scientific priorities.
As our customers’ needs have evolved, so have our capabilities. We have become experts in scientific operations, improving performance with sophisticated solutions and providing guidance on best practices.
You can select and customize services for peak efficiency, quality, and accelerated innovation.
The Equipment & Instrument Service Team’s focus is to provide comprehensive service solutions for our customers. We provide validation, calibration, preventative maintenance, and extended warranties on all equipment & instruments in and around the laboratory.
Description:
Low Shrinkage - fast curing, cold polymerizing, three-component resin, based on modified polyester, available in powder, syrup I, and syrup II form. Excellent margin fit, optimum grinding, and polishing properties.
Description:
Antifadent Mountant Solutions Medium for immunofluorescence. Overcomes the problems of fading. Designed to reduce the fading of the fluorescence of dyes.
Description:
for bonding strain gages & special-purpose sensors, useful in temperatures from -452°F to+700°F (-269°C to+370°C), Shelf Life & Post Life:At room temperature approximately 3 months, Once mixed has room temperature pot life of 2 weeks, Cur
Description:
excellent adhesion to metals, glass, and ceramic, for precise high purity work, leaves no residue after dissolving, does not clog100497-424
Description:
contains Zinc Chloride and used in the same manner as Zenker’s stock solution, the staining results produced by this fixative are comparable to those of Zenker’s Stock solution, due to the hazardous nature of mercury, Zenker’s fluid is no longer available
Description:
Consideration of these oils is also suggested where stage temperatures are elevated by sub-stage illuminators and high wattage projection equipment.
Description:
It has a refractive index (nD at 25[degree]C) of 1.605 and an Abbe V dispersion of 30, making it appropriate for mounting Asbestiform Tremolite, Anthophyllite, and Actinolite.
Description:
Offers advantage of working with unfixed tissues at low temperatures, many fixation-sensitive procedures carried out in 1-4 microns resin sections at -25[degree]C. Consists of: 500ml LR Gold Resin, 100g Polyvinylpyrolidone, 50g Benzoyl Peroxide, 50g Benzil
Description:
Resin, Lowicryl resins are highly cross-linked acrylate-based embedding resins, designed for use over a wide range of embedding conditions. These resins provide low viscosity at low temperatures.
Description:
Very low viscosity (8cps), non-toxic resin. Polar monomer polyhydroxylated acromatic acrylic resin. Cured by heat or UV light. Sections of polymerized resin are hydrophilic. Consists of: 500ml LR White Resin, 10ml UV accelerator
Description:
Permanent medium designed for preservation of immunohistochemical organic insoluble chromogen substrates, used either manually or in automated coverslipper for histology and cytology applications, contains no solvents
Description:
It is a gold-filled conductive bonding, exhibiting high electrical conductivity and bond strength. Suited to all SEM work, and it bonds well to alumina ceramic substrate, phenolic circuit boards, and transistor headers.
Description:
excellent adhesion to metals, glass, and ceramic, for precise high purity work, leaves no residue after dissolving, does not clog the diamond wheel offers maximum adhesion to subminiature parts
Description:
Glycerol-phosphate buffered saline based mountant. Addition of antifadent is to retard bleaching of fluorochromes. Useful for high magnification work. Both solutions are medium viscosity, and water-clear. CFM-1 Plus Antifaden
Description:
Luft's Formula. Polymerization takes place overnight so blocks can be sectioned the next day. J. Biochem. Biophy. Cytol. 9, 409 (1961). Kit consists of:, 450ml Araldite 502, 450ml DDSA; Specially Distilled, *50ml DMP-30
Description:
Pre-filled cups. Used as a fixation and staining fluid. Packed in leak-proof histo-containers, prefilled, ready-to-use. Formulated with Picric Acid saturated aqueous solution 75%, Formalin (40% aqueous formaldehyde) 25% and Glacial Acetic acid 5% in de-ionized water
Description:
A mixture of xylene - mixed isomers and non hazardous ingredients to offer a very good synthetic mountant. Once dried the refractive index is 1.58.
Description:
Mixture of Butyl and Methyl Methacrylate. Can be UV cured in cold or heat cured. Resin can be removed from sections with solvent (acetone) before staining. 225 ml Methyl Methacrylate, 225 ml Butyl Methacrylate
Description:
is supplied as a single component-ready to use pre-mixed resin. Micro-Bed can be polymerized in either EMS embedding capsules or gelatin capsules by either heat(55-65[degree]C) or UV (wavelength 365nm) light at low temperatures
Description:
Permanent medium designed for preservation of immunohistochemical organic insoluble chromogen substrates, used either manually or in automated coverslipper for histology and cytology applications, contains no solvents
Description:
Premixed, prebuffered fixatives, pH adjusted for immediate use. Freshly prepared for maximum shelf life. Immediate fixation of specimens without transfer. 0.2% Formaldehyde/0.1% Chromic Acid in 0.1
Description:
Durcupan, Water Soluble, A water soluble embedding medium for EM based on an aliphatic polyepoxide. A Fluka A.G. Buchs. Switzerland-Registered Trademark. Single Component B
Description:
Mounting media for cover glass. It comes in a convenient dispensing tube or bottle. Solvent based which is soluble in xylene and has a 10 minute dry time. Its viscosity is 33 cps ar 25[degree].
Description:
Water soluble embedding media based on Glycol Methacrylate plastic embedding. Intended use in preparing samples for high resolution microscopes . The catalyzed monomer acts as dehydration and infiltration agent. JB-4 Solution A only
Description:
excellent adhesion to metals, glass, and ceramic, for precise high purity work, leaves no residue after dissolving, does not clog the diamond wheel, offers maximum adhesion to subminiature parts
Description:
Instant conductive silver traces. Valve tip allows very smooth flow with normal writing pressure. Spring loaded. For conductivity traces, solderable termination's are possible. Tin, lead, or silver solder can be used. Silver content
Description:
Stain Aqueous Clarifier Type 1, Clarifier is a uniquely formulated buffer that enhances cytoplasmic details, increases cell transparency and helps eliminate background staining, Convenient and ready-to-use, Size: 1 gal
Description:
For Normal Light Microscopy - The greater the gap between cover glass and objective, or condenser and slide, the more desirable high viscosity becomes. For extremely large gaps, type NVH should be used.
Description:
For microscopy. A mixture of Distyrene, a plasticizer, and xylene. A colorless synthetic resin mounting media which replaces Xylene-Balsam. It preserves the stain and dries quickly.
Description:
Acrytol, rapid-drying mounting medium, low viscosity, prevents air bubbles, contains an antioxidant to inhibit stain fading and prevent the formulation of annual rings, 1Pint
Description:
Very low viscosity (8cps), non-toxic resin. Polar monomer polyhydroxylated acromatic acrylic resin. Cured by heat or UV light. Sections of polymerized resin are hydrophilic. Consists of: 500ml LR White Resin, 10ml UV accelerator